Challenge: A manufacturer of all-terrain,
all season, track-driven vehicles was experiencing
a leakage problem from the transmission case of
one of their vehicles that was used primarily
for trail development for cross-country ski trails
or snowmobiles. Initially the company tried standard
compression-type metal cord connectors to stop
the leaking. But they did not have consistent
success as the seals around the individual conductors
were not reliable due to the lubricity of the
transmission fluid. In addition, the chemical
reaction of the wire jacketing material used in
the cord connector was also of concern.
The Remke Solution:To
meet the demanding environment within the transmission
case, the Remke Custom Solutions Team needed to
develop a connector that could withstand being
immersed in the transmission fluid for extended
periods of time and would not leak. The team designed
a completely new type of 6-pole Mini-Link connector.
They used epoxy potting compound instead of overmolding
material, and utilized Teflon wire instead of
the standard 16 or 18 AWG cable to better resist
the chemical breakdown from the transmission fluid.
The end result was a unique design; a potted,
pass-thru electrical connector with potted wires
at both ends of the connector so that the wires
can pass through from the inside of the transmission
to the outside.
The Remke Solution solved the leakage problem
and provided the manufacturer with the industrial,
heavy-duty connection they desired. The company
was so pleased with the results plus the design
& function of the Remke custom connector that
they continue to purchase a quantity of these
products on a regular basis today.
If you have a tough application challenge,
contact the Remke Custom Solutions Team today.